Plateforme
java
Composant
ignition
Corrigé dans
8.1.32
CVE-2023-50233 is a Remote Code Execution (RCE) vulnerability affecting Inductive Automation Ignition versions 8.1.31 through 8.1.31. This flaw allows an attacker to execute arbitrary code on a vulnerable system by manipulating a user-supplied path within the getJavaExecutable method. User interaction is required, specifically connecting to a malicious server. A patch is available from Inductive Automation to resolve this issue.
Successful exploitation of CVE-2023-50233 grants an attacker the ability to execute arbitrary code on the affected Ignition server. This could lead to complete system compromise, including data exfiltration, modification, or deletion. The attacker could potentially gain control of the entire industrial control system (ICS) or SCADA environment where Ignition is deployed, leading to significant operational disruption and potential safety hazards. The requirement for user interaction limits the immediate exploitability, but a phishing campaign or social engineering attack could be used to trick users into connecting to a malicious server.
CVE-2023-50233 was publicly disclosed on May 3, 2024. The vulnerability's reliance on user interaction may limit its immediate exploitability, but the potential for severe impact warrants careful attention. No known active exploitation campaigns have been publicly reported at the time of writing. The vulnerability is not currently listed on the CISA KEV catalog.
Organizations utilizing Inductive Automation Ignition for industrial control and SCADA applications are at risk. This includes critical infrastructure sectors such as manufacturing, energy, and utilities. Specifically, deployments with limited network segmentation or inadequate user awareness training are particularly vulnerable.
• linux / server: Monitor Ignition server logs for unusual connection attempts or errors related to file access. Use journalctl -u ignition to filter for relevant events.
journalctl -u ignition | grep -i "java executable"• java: Examine Java process arguments for suspicious paths or command-line parameters. Use ps aux | grep ignition to list running processes and their arguments.
• generic web: Monitor web server access logs for requests targeting the getJavaExecutable endpoint with unusual parameters. Use grep to search for suspicious patterns in the logs.
grep -i "java executable" /var/log/apache2/access.logdisclosure
Statut de l'Exploit
EPSS
3.65% (percentile 88%)
CISA SSVC
Vecteur CVSS
The primary mitigation for CVE-2023-50233 is to upgrade to a patched version of Inductive Automation Ignition. Inductive Automation has released a fix, and users should apply it as soon as possible. If immediate patching is not feasible, consider implementing network segmentation to limit the potential impact of a successful exploit. Restrict network access to the Ignition server to only authorized users and systems. Monitor network traffic for suspicious connections to unknown or untrusted servers. While a WAF may not directly prevent this vulnerability, it can help detect and block malicious requests. After upgrade, confirm the fix by attempting to connect to a known malicious server and verifying that the connection is rejected.
Actualice Inductive Automation Ignition a una versión posterior a la 8.1.31 para corregir la vulnerabilidad de recorrido de directorio. Esto evitará la ejecución remota de código arbitrario. Asegúrese de que los usuarios no se conecten a servidores no confiables.
Analyses de vulnérabilités et alertes critiques directement dans votre boîte mail.
CVE-2023-50233 is a Remote Code Execution vulnerability in Inductive Automation Ignition versions 8.1.31–8.1.31, allowing attackers to execute code via a malicious server connection. It has a HIGH severity rating (CVSS 8.8).
If you are running Inductive Automation Ignition versions 8.1.31 through 8.1.31, you are potentially affected by this vulnerability. Upgrade to a patched version as soon as possible.
The recommended fix is to upgrade to a patched version of Inductive Automation Ignition. Refer to Inductive Automation's advisory for specific version details and upgrade instructions.
No active exploitation campaigns have been publicly reported at this time, but the potential for severe impact warrants immediate attention and mitigation.
Please refer to the Inductive Automation security advisory for detailed information and mitigation steps: [https://inductiveautomation.com/security/](https://inductiveautomation.com/security/)
Téléverse ton fichier de dépendances et découvre instantanément si cette CVE et d'autres te touchent.
Téléverse ton fichier pom.xml et nous te dirons instantanément si tu es affecté.